Review



virtual touch tissue imaging and quantification software  (Siemens Healthineers)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Siemens Healthineers virtual touch tissue imaging and quantification software
    Virtual Touch Tissue Imaging And Quantification Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pm39842258-51-25-27
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Software:

    Article Title: Acoustic radiation force impulse-imaging in the assessment of liver fibrosis in children.
    Article Snippet: Background Acoustic radiation force impulse-imaging (ARFI) uses sound waves to interrogate the mechanical stiffness of a tissue.. Objective To determine the usefulness of ARFI for estimating liver fibrosis in children.. Materials and methods A prospective masked study of children with chronic liver disease (CLD) and/or before liver transplant (LT) comparing ARFI with histopathological analysis.

    Article Title: Interpretation US Elastography in Chronic Hepatitis B with or without Anti-HBV Therapy
    Article Snippet: .. ARFI imaging was mainly carried out with Acuson S2000 (Siemens Healthcare, Erlangen, Germany) and Virtual Touch tissue quantification software (Siemens Healthcare). ..

    Article Title: Is there a correlation between the femoral anteversion angle and the elasticity of the hip muscles in cases of intoeing gait due to increased femoral anteversion angle?
    Article Snippet: .. Quantitative muscle elasticity was measured by the Virtual Touch tissue quantification software (Siemens Medical Solutions) without pressure to the transducer. ..

    Article Title: Acoustic radiation force impulse elastography: a tool for muscle aging assessment: a pilot study
    Article Snippet: .. Acoustic radiation force impulse ultrasound elastography quantification was performed using Virtual Touch Tissue Quantification software (Siemens Medical Solutions). ..

    Article Title: Liver and spleen stiffness measured by acoustic radiation force impulse elastography for noninvasive assessment of liver fibrosis and esophageal varices in patients with chronic hepatitis B.
    Article Snippet: epatitis B, which is caused by the hepatitis B virus (HBV), is a potential life-threatening liver infection and the most serious type of viral hepatitis.. As the World Health Organization reported,1 approximately 2 billion people have been infected with HBV worldwide, and more than 350 million people have chronic hepatitis B.. In China, the most common viral hepatitis is type B.

    Article Title: Hepatic and splenic sonographic and sonoelastographic findings in pulmonary arterial hypertension
    Article Snippet: .. Blinded to the clinical and laboratory data, a single radiologist with more than 5 years of experience with pSWE performed B-mode standard US scanning and pSWE in the same session, using a US device (Acuson S2000) with Virtual Touch tissue quantification software (Siemens Medical Solutions USA, Inc., Mountain View, CA, USA). ..

    Article Title: Acoustic Radiation Force Impulse Imaging in Paediatric Patients
    Article Snippet: .. The examinations were performed using an ultrasound device, Acuson S2000 (Siemens Medical Solutions, Mountain View, CA), equipped with a 4-MHz transducer, with Virtual Touch Tissue Quantification software (Siemens Medical Solutions) to measure SWV. ..

    Shear:

    Article Title: Acoustic radiation force impulse-imaging in the assessment of liver fibrosis in children.
    Article Snippet: Background Acoustic radiation force impulse-imaging (ARFI) uses sound waves to interrogate the mechanical stiffness of a tissue.. Objective To determine the usefulness of ARFI for estimating liver fibrosis in children.. Materials and methods A prospective masked study of children with chronic liver disease (CLD) and/or before liver transplant (LT) comparing ARFI with histopathological analysis.

    Imaging:

    Article Title: Interpretation US Elastography in Chronic Hepatitis B with or without Anti-HBV Therapy
    Article Snippet: .. ARFI imaging was mainly carried out with Acuson S2000 (Siemens Healthcare, Erlangen, Germany) and Virtual Touch tissue quantification software (Siemens Healthcare). ..



    Similar Products

    90
    Siemens AG virtual touch tissue quantification software
    Virtual Touch Tissue Quantification Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pm40481134-150-6-11
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue imaging and quantification software
    Virtual Touch Tissue Imaging And Quantification Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pm39842258-51-25-27
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue imaging quantification (vtiq) software
    Virtual Touch Tissue Imaging Quantification (Vtiq) Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc11306866-94-14-25
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging quantification (vtiq) software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens AG virtual touch tissue imaging and quantification (vtiq) software
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Imaging And Quantification (Vtiq) Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc11088583-105-87-81
    Average 90 stars, based on 1 article reviews
    virtual touch tissue imaging and quantification (vtiq) software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue quantification software
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Quantification Software, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc09009350-79-7-12
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe
    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding <t>VTIQ</t> parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The <t>mean</t> <t>SWV</t> was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s
    Virtual Touch Tissue Quantification (Vtq) Software With A 6c1 Hd Convex Probe, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/virtual+touch+tissue+quantification+software/virtual+touch+tissue+quantification/pmc08446499-84-17-9
    Average 90 stars, based on 1 article reviews
    virtual touch tissue quantification (vtq) software with a 6c1 hd convex probe - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s

    Journal: Insights into Imaging

    Article Title: Assessing the treatment response of lateral elbow tendinopathy using time-dependent ultrasonography, Doppler imaging, and elastography

    doi: 10.1186/s13244-024-01695-8

    Figure Lengend Snippet: SWE of the right elbow in the same 49-year-old man with chronic lateral tendinopathy. a Baseline long-axis SWE of the common extensor tendon and radial collateral ligament complex shows the ROI. b Corresponding VTIQ parametric velocity map with three equidistant ROI placed within the tendon, aligned from the apex to the base of the epicondyle to measure the local SWVs. The mean SWV was 5.55 m/s. c At the 6-month follow-up exam, the mean SWV was 8.29 m/s. d At the 12-month follow-up exam, the mean SWV was 9.15 m/s

    Article Snippet: The entire tendon was scanned, capturing the area with the highest neovessel density. a Baseline long-axis US with Power Doppler imaging reveals pixels of Doppler signal covering around 50% of the tendon surface, indicating Grade 2 neovascularity. b Following tendon fenestration treatment, the 6-month follow-up long-axis US displays partial neovessel regression, with a few pixels of Doppler signal indicating Grade 1 neovascularity. c The 12-month follow-up long-axis US exhibits a nearly complete resolution of the Doppler signal (Grade 1 neovascularity) Using Siemens’s virtual touch tissue imaging and quantification (VTIQ) software, we assessed SWV on a long-axis image depicting the minor groove at the base of the lateral humeral epicondyle.

    Techniques: